Selamat Datang!
Gabung Sekarang
|
Masuk
Menu Anggota
|
Bantuan
|
0
SEMUA
PRODUK
JUAL
BELI
PERUSAHAAN
Mengenalkan Indotrade.co.id kepada teman
*
artinya harus diisi
*
Nama Anda:
*
Email Anda:
*
Email Teman Anda: :
Untuk mengirim lebih dari satu orang, pisahkan setiap email dengan koma.
Contoh: nama1@domain.co.id, nama2@domain.co.id dan seterusnya
*
Pesan:
Halo, Saya Pebisnis Saya mengenal produk ini dari https://www.indotrade.co.id dan saya lihat hal ini mungkin berguna untuk anda. ------------------------------------------------------- STANHOPE SETA, Quantum Oxidation Tester TFOUT -Thin-Film Oxygen Uptake Test RPVOT -Rotating Pressure Vessel Oxidation Test SPESIFICATION: Methods & Specifications: ASTM D 4742, D7098, D 2272, IP 229 Application: Used in a number of tests evaluating formulated engine oils, turbine oils, and base oil oxidation resistance. Meets methods ASTM D2272, D4742, D7098 and IP229. Principle: A small quantity of oil ( 1.5 g for D4742 and 50 g for D2272) is mixed with or brought in contact with catalyst within an oxygen pressurized chamber. The oil sample is rotated at 100 RPM until the recorded oxygen pressure in the chamber falls rapidly and signals the end of the test. The Quantum design in unique in operating without need for a hot, liquid bath. This makes all preparations for test, return to test, and general operation, simple and direct – decreasing test turn-around and interchangeability between methods. Dimensions: – Bench-top footprint: 8" w x 15" d x 12" h ( 20 x 38 x 30.5 cm) , Weight: - 20 lbs. ( 9 kg) Voltage: – 120 VAC, Single Phase, 15 Amp. 50/ 60 Hz. ( Also available in 220 VAC, 50 or 60 Hz) Heating Medium: – Non-liquid ‘ Dry Cylinder’ heating system – no hot oil bath. Testing Capacity: – Single position stainless steel oxidation vessel with pressure transducer. – Designed for multiple unit ( side-by-side) alignment on the bench-top, each functioning independently. Test Parameter Capabilities: – Temperature – Choice of operating temperatures ( 200 ± 0.1° C recommended maximum) – Oxygen Charge – Choice of pressure ( 100 ± 0.1 psi recommended maximum) – Vessel Rotation – Variable speed control Read-out: – Temperature controller and pressure meter mounted on cabinet front for easy viewing of parameters throughout test – no separate console box. – Continuous temperature and oxygen pressure output through Digital USB to Computer or Dsub9 connector to Analog chart recorder. Safety: – Oxidation vessel tested under pressures of 500 psig ( 3450 KPa) -- 300% of maximum test pressure – Current limiting fuses – Over-pressure sensor & relief – Over-temperature cut-out fuse Untuk informasi selengkapnya, silahkan ke http://www.indotrade.co.id/karuniamakmur/2438386
0.6996 194.163.150.105